ORing’s TransporterTM series Ethernet switches are designed for industrial applications, such as rolling stock, vehicle, and railway. The TES-1080-M12-BP2, which is compliant with the EN50155 standard, is an unmanaged Ethernet switch with 8×10/100Base-T(X) ports (4 of these ports also double as 2 sets of bypass ports). TES-1080-M12-BP2 is constructed of a rugged aluminum case and designed with Ethernet ports (M12 type connector), which provide a dust-tight connection. TES-1080-M12-BP2 EN50155 Ethernet switch use M12 connectors to ensure tight, robust connections, and guarantee reliable operation against environmental disturbances, such as vibration and shock. TES-1080-M12-BP2 includes 2 sets of bypass ports that protect the network from failures and Network maintenance by ensuring network integrity during power loss. Each set of these bypass ports includes Network ports and Monitor ports. The Network ports are used for connection to main-network connections and provide protection mechanism, and the Monitor ports are used for down-linking local networking device. When the power is on, the operating mode of the Bypass ports is set to Normal, and the local networking device is connected with main-network. When power failure occurs, the Bypass ports are swiftly set to bypass mode to isolate the main-network from the local networking device. In addition, the wide operating temperature range from -40 oC to 70oC can satisfy most of operating environment. Therefore, the switch is one of the most reliable choices for rolling stock Ethernet application.
Feature :
- Industry-leading EN50155-compliant Ethernet switch for railway applications
- Supports auto-negotiation and auto-MDI/MDI-X
- Supports store-and-forward transmission
- Supports flow control
- Built-in 2 sets of bypass ports
- Warning system by relay output
- Ultra-rugged enclosure for toughest industrial usages
- M12 connectors to guarantee reliable operation against environmental disturbances
- Dual wide-range 12~48V power inputs on the M23 connector
- Wall mounting enabled
Specification :
ORing Switch Model | TES-1080-M12-BP2 |
Physical Ports | |
10/100 Base-T(X) Ports in M12 (D-coding) Auto MDI/MDIX | 8 |
Technology | |
Ethernet Standards | IEEE 802.3 for 10Base-T IEEE 802.3u for 100Base-TX IEEE 802.3x for Flow control |
MAC Table | 8192 MAC addresses |
Processing | Store-and-Forward |
LED Indicators | |
Power Indicator | Green : Power LED x 2 |
Fault Indicatorr | Amber : Indicate unexpected event occurred |
10/100Base-T(X) M12 Port Indicator | Green for port Link/Act. Amber for Duplex/Collision |
Fault contact | |
Relay | Relay output to carry capacity of 3A at 24VDC on M12 connector (A-coding) |
Power | |
Redundant Input Power | Dual 12~48VDC on M23 connector |
Power Consumption (Typ.) | 5 Watts |
Overload Current Protection | Present |
Reverse Polarity Protection | Present |
Physical Characteristic | |
Enclosure | IP-40 |
Dimension (W x D x H) | 125 (W) x 65 (D) x 196 (H)mm |
Weight (g) | TBD |
Environmental | |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Operating Temperature | -40 to 70°C (-40 to 158°F) |
Regulatory approvals | |
EMI | FCC Part 15, CISPR (EN55022) class A, EN50155 (EN50121-3-2, EN55011, EN50121-4) |
EMS | EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-9, EN61000-4-11 |
Shock | IEC60068-2-27, EN61373 |
Free Fall | IEC60068-2-32 |
Vibration | IEC60068-2-6, EN61373 |
Safety | EN60950-1 |
Warranty | 5 years |