Industrial RS-232 to RS-422/485 converters with 2 KV isolation
The TCC-100 and TCC-100I are RS-232 to RS-422/485 converters that increase networking capability by extending the RS-232 transmission distance. Both converters have a superior industrial-grade design that includes DIN-rail mounting, terminal block wiring, external terminal block for power, and optical isolation (TCC-100I only). The TCC-100/100I are ideal solutions for converting RS-232 signals to RS-422/485 in critical industrial environments.
Feature :
Features and Benefits
- RS-232 to RS-422 conversion with RTS/CTS support
- RS-232 to 2-wire or 4-wire RS-485 conversion
- 2 KV isolation protection (TCC-100I/TCC-100I-T)
- Wall and DIN-rail mounting
- Plug-in terminal block for easy RS-422/485 wiring
- LED indicators for power, Tx, Rx
- -20 to 60°C operating temperature
- Wide temperature model available (-40 to 85°C )
Diagram :
Specification :
• RS-232 Side | |
Connector | DB9 female |
Signals | TxD, RxD, RTS, CTS, GND |
• RS-422/485 Side | |
Connector | Terminal Block |
Signals | (interface selected by DIP switch) RS-422: TxD+, TxD-, RxD+, RxD-, RTS, CTS, GND RS-485-4w: TxD+, TxD-, RxD+, RxD-, GND RS-485-2w: Data+, Data-, GND |
RS-485 Data Direction Control | ADDC® (automatic data direction control) |
• Serial Communication | |
Baudrate | 50 bps to 921.6 Kbps |
ESD Protection | 15 KV |
Optical Isolation | 2 KV (TCC-100I/100I-T) |
• Physical Characteristics | |
Housing | Aluminum |
Dimensions | 67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in) |
Weight | 148 ± 5 g |
• Environmental Limits | |
Operating Temperature | Standard Models: -20 to 60°C (-4 to 140°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Power Requirements | |
Source of Input Power | Power input jack |
Input Voltage | 12 to 48 VDC |
Power Consumption | TCC-100/100-T: 85 mA @ 12 V TCC-100I/100I-T: 150 mA @ 12 V |
Voltage Reversal Protection | Protects against V+/V- reversal |
Over Current Protection | Protects against two signals shorted together |
• Standards and Certifications | |
Safety | UL 60950-1 |
EMC | CE, FCC |
EMI | FCC Part 15 Subpart B Class B |
EMS | IEC 61000-4-2 (ESD) Level 2, IEC 61000-4-3 (RS) Level 2, IEC 61000-4-4 (EFT) Level 2, IEC 61000-4-5 (Surge) Level 2, IEC 61000-4-6 (CS) Level 2, IEC 61000-4-8 (SFMF) Level 1 |
Green Product | RoHS, CRoHS, WEEE |
• MTBF (mean time between failures) | |
Time | 3,017,857 hrs |
Database | MIL-HDBK-217F |
• Warranty | |
Warranty Period | 5 years |
Details | See http://www.moxa.com/support/warranty.htm |