ioLogik E1214-TEthernet Remote I/O with 2-port Ethernet switch, 6 DIs, and 6 Relays

A new daisy-chained Ethernet I/O concept is now available. The ioLogik E1214 industrial Ethernet remote I/O has two embedded Ethernet switch ports that allow information to flow to another local Ethernet device or connect to the next ioLogik in the daisy-chain.

Applications such as factory automation, security and surveillance systems, and tunnel monitoring, can make use of daisy-chained Ethernet for building multi-drop I/O networks over standard Ethernet cables. Many industrial automation users are familiar with the multi-drop configuration typically used in fieldbus applications. The daisy-chain function on the Ethernet remote I/O ioLogik E1214 not only increases the connection between machines and panels, but also lowers the cost of buying separate Ethernet switches, and at the same time reduces labor fees and cabling by a large percentage. For example, if a production facility contains 700 stations (20 points per station), the wiring cost reduction can reach 15% of the total implementation cost.

Saving Time and Wiring Costs with Peer-to-Peer Communications

In remote automation applications, the control room and sensors are often far removed, making wiring over long distances a constant challenge. With peer-to-peer networking, users may now map a pair of ioLogik E1200 series modules so that input values will be directly transferred to output channels, greatly simplifying the wiring process and reducing wiring costs.

User-definable Modbus/TCP Addressing for Painless Upgrading of Existing Systems

For Modbus devices that are controlled and detected by fixed addresses, users need to spend a vast amount of time researching and verifying the configurations. Users need to locate each device’s networking details like I/O channels, or vendor-defined addresses to enable the initial or start address of a SCADA system or PLC. The ioLogik E1200, with user-definable Modbus/TCP addressing, offers greater flexibility, and setup is easy. Instead of worrying about individual devices, users simply configure the function and address map to fit their needs.

Feature :

The Green Core Product Identity of the ioLogik series will be phased in starting May 1, 2014. During the product transition period, you may still receive products that use the previous panel design. Please click here to learn more about Moxa’s Green Core product transition.

Features and Benefits 

  • Support Modbus/TCP Protocol
  • Active communication with patented Active OPC Server
  • 2-port Ethernet switch for daisy-chain topologies
  • Easy mass deployment and configuration with ioSearch utility
  • Save time and wiring cost with peer-to-peer communication
  • User-defined Modbus/TCP addressing
  • Simplify I/O managment with MXIO library on either Windows or Linux platform
  • Supports SNMPv1/v2c
  • UL/cUL Class I Division 2, ATEX Zone 2 certification
  • Wide operating temperature: -40 to 75°C ( -40 to 167°F )

Diagram :

Diagram ioLogik E1214-T-1

Diagram ioLogik E1214-T-2

Specification :

• LAN
Ethernet 2 x 10/100 Mbps switch ports, RJ45
Protection 1.5 kV magnetic isolation
Protocols Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, HTTP
• Power Requirements
Power Input 24 VDC nominal, 12 to 36 VDC
• Physical Characteristics
Wiring I/O cable max. 14 AWG
Dimensions 27.8 x 124 x 84 mm (1.09 x 4.88 x 3.31 in)
Weight Under 200 g
Mounting DIN rail or wall
• Environmental Limits
Operating Temperature Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 75°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
Altitude Up to 2000 m
Note Please contact Moxa if you require products guaranteed to function properly at higher altitudes.
• Standards and Certifications
Safety UL 508
EMI EN 55022; EN 61000-3-2; EN 61000-3-3;
FCC Part 15, Subpart B, Class A
EMS EN 55024, EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6,
EN 61000-4-8, EN 61000-4-11
Shock IEC 60068-2-27
Freefall IEC 60068-2-32
Vibration IEC 60068-2-6
Green Product RoHS, CRoHS, WEEE
Hazardous Location UL/cUL Class I Diision 2, ATEX Zone 2
• Warranty
Warranty Period 5 years (excluding ioLogik E1214)
Details See www.moxa.com/warranty
Note Because of the limited lifetime of power relays, products that use this component are covered by a 2-year warranty.
E1214 Specifications
• Inputs and Outputs
Digital Inputs 6 channels
Relay Outputs 6 channels
Isolation 3K VDC or 2K Vrms
• Digital Input
Sensor Type Wet Contact (NPN or PNP), Dry Contact
I/O Mode DI or Event Counter
Dry Contact • On: short to GND
• Off: open
Wet Contact NPN (DI to GND):
• On: 0 to 3 VDC
• Off: 10 to 30 VDC
PNP (DI to GND):
• Off: 0 to 3 VDC
• On: 10 to 30 VDC
Common Type 6 points per COM
Counter Frequency 250 Hz, power off storage
Digital Filtering Time Interval Software selectable
• Relay Output
Type Form A (N.O.) power relay
Contact Current Rating Resistive Load: 5 A @ 30 VDC, 250 VAC, 110 VAC
Breakdown Voltage 500 VAC
Relay On/Off Time 1500 ms (max.)
Initial Insulation Resistance 1000 M ohms (min.) @ 500 VDC
Mechanical Endurance 5,000,000 operations
Electrical Endurance 100,000 operations @ 5 A resistive load
Contact Resistance 100 m ohms (max.)
Pulse Output 0.3 Hz at rated load
Note Ambient humidity must be non-condensing and remain between 5 and 95%. The relays of the ioLogik E1214 may malfunction when operating in high condensation environments below 0° Celsius.
• Power Requirements
Power Consumption 188 mA @ 24 VDC
• MTBF (mean time between failures)
Time 808,744 hrs
Database Telcordia (Bellcore)