Feature :

Features and Benefits
  • PoE+ injector for 10/100/1000M networks; inject power and data to PD (Power Device) equipment
  • IEEE 802.3af/at compliant; supports a full 30 watt output
  • 24/48 VDC wide range power input
  • -40 to 75°C operating temperature range (T model)

Introduction

The INJ-24 is an IEEE 802.3at PoE+ injector that combines power and data and delivers them to a powered device over one Ethernet cable. Designed for power-hungry devices, the INJ-24 injector provides up to 30 watts, twice as much as conventional PoE injectors. The -40 to 75oC wide temperature range design makes the INJ-24 perfect for operating in critical industrial environments.

Patent Marking

Diagram :

Specification :

• Technology
Standards IEEE 802.3af/at for Power-over-Ethernet IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3ab for 1000BaseT(X)
• Interface
RJ45 Ports 10/100/1000BaseT(X) for PoE OUT and DATA IN
PoE Pinout V+, V+, V-, V- for pin 4, 5, 7, 8 (Midspan, MDI Alternative B)
• Power Requirements
Input Voltage 24/48 VDC, single input
Operating Voltage 22 to 57 VDC
Input Current 1.42 A @ 24 VDC
Overload Current Protection Present
Connection 1 removable 3-contact terminal block
Reverse Polarity Protection Present
Power Consumption Max. 4.08 W full loading without PD’s consumption
Power Budget Max. 30 W for 1 PD’s consumption
• Physical Characteristics
Housing Plastic
IP Rating IP30 protection
Dimensions 24.9 × 100 × 86.2 mm (0.98 x 3.93 x 3.39 in)
Weight 115 g (0.26 lb)
Installation DIN-rail mounting
• Environmental Limits
Operating Temperature Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
• Standards and Certifications
Safety UL 508, EN 60950-1 (LVD)
EMC EN 55032/24
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: Signal: 10 V IEC 61000-4-8
Shock IEC 60068-2-27
Freefall IEC 60068-2-32
Vibration IEC 60068-2-6
Note: Please check Moxa’s website for the most up-to-date certification status.
• MTBF (mean time between failures)
Time 2,525,278 hrs
Standard Telcordia (Bellcore), GB
• Warranty
Warranty Period 5 years
Details See www.moxa.com/warranty