TRENDnet’s TI-G62 is a reliable IP30 unmanaged DIN-rail switch with hardened components rated for extreme industrial environments. It offers 5 Gigabit Ethernet ports, one shared SFP slot, one dedicated SFP slot, and a 12 Gbps switching capacity. DIP switches toggle between the shared Gigabit port and SFP slot and set supported throughput to either 100 Mbps or 1 Gbps. Dual redundant power inputs (power supply sold separately: TI-M6024) and a power failure alarm output trigger support zero downtime applications.
- 5 x Gigabit Ethernet ports
- 1 x shared SFP slot and 1 x dedicated SFP slot
- 12 Gbps switching capacity
- Hardened IP30 rated metal switch
- Includes DIN-rail and wall mounts
- Extreme -40 to 75 ºC (-40 to 167 ºF) operating temperature range
- Dual redundant power inputs with overload current protection
- Alarm output triggered by power failure
- Power supply sold separately (model TI-M6024)
- Limited Lifetime Warranty*
Network Ports 5 x Gigabit Ethernet ports, 1 x shared SFP slot (shared with Ethernet port 5 and features a supply 100/1000 Mbps DIP switch) and 1 x dedicated SFP slot |
|
DIN-Rail/Wall Mounts IP30 rated metal enclosure with included DIN-rail and wall mount hardware |
|
Switching Capacity 12 Gbps switching capacity |
|
Redundant Power Dual redundant power inputs with overload current protection (power supply sold separately: model TI-M6024) |
|
Alarm Output Alarm output triggered by power failure of primary and/or redundant power |
|
Jumbo Frame Sends larger packets, or Jumbo Frames (up to 9 KB), for increased performance |
|
Extreme Temperatures Hardened switch is rated for an operating temperature range of -40 to 75 ºC (-40 to 167 ºF) |
|
Electro Magnetic Compliance Complies with FCC Part 15 Subpart B Class A and CE EN 55022 Class A standards |
|
Certifications Rated for information technology (ITE) equipment (EN55022/24); industrial, scientific, and medical (ISM) Equipment (EN55011) |
|
Shock and Vibration Resistant Rated for shock (IEC 60068-2-27), freefall (IEC 60068-2-32), and vibration (IEC 60068-2-6) |
|
Grounding Point Grounding point protects equipment from external electrical surges |
Diagram :
Specification :
Standards
- IEEE 802.3
- IEEE 802.3u
- IEEE 802.3ab
- IEEE 802.3z
- IEEE 802.3x
Device Interface
- 5 x Gigabit ports
- 1 x Shared SFP slot (port F5)
- 1 x Gigabit SFP slot (port F6)
- 6-pin removable terminal block
- LED indicators
- DIP switch
- DIN-Rail mount
- Wall mount
- Grounding point
Data Transfer Rate
- Ethernet: 10 Mbps (half duplex), 20 Mbps (full duplex)
- Fast Ethernet: 100 Mbps (half duplex), 200 Mbps (full duplex)
- Gigabit: 2000 Mbps (full duplex)
Performance
- Data RAM Buffer: 1024 KB
- Switching Fabric: 12 Gbps
- MAC Address Table: 2 K entries
- Jumbo Frame: 9 KB
- Forwarding rate: 8.9 Mpps (64-byte packet size)
Special Features
- Hardened components rated for extreme temperatures
- Dual redundant power inputs
- Auto-Negotiation
- Auto store and forward architecture
- Automatic address learning and address aging
- ESD 8 KV and Surge 6 KV protection
Power
- Input: 12 – 56 V DC
- Compatible power supply: TI-M6024 (sold separately)
- Consumption: Max. 3.84 Watts
Terminal Block
- Redundant power inputs, alarm relay contact, 6 pin
- Wire range: 0.34 mm^2 to 2.5 mm^2
- Solid wire (AWG): 12-24/14-22
- Stranded wire (AWG): 12-24/14-22
- Torque: 5 lb. – In / 0.5 Nm / 0.56 Nm
- Wire strip length: 7-8 mm
DIP Switch
- 1: set port 5 to copper port or SFP slot
- 2: set port 5 to 100 Mbps or 1000 Mbps on SFP slot
Alarm Relay Contact
- Relay outputs with current carrying capacity of 1 A, 24 V DC
- Short circuit mode when two power sources are connected
- Open circuit mode when only one power source is connected
MTBF
- 510,304 hours
Housing
- IP30 metal case
- DIN-rail mount
- Wall mount
- Grounding point
- 8 KV ESD protection
- 6 KV surge protection
Operating Temperature
- – 40 to 75 °C (-40 to 167 °F)
Operating Humidity
- Max. 95 % non-condensing
Dimensions
- 143 x 104 x 36 mm (5.6 x 4.1 x 1.4 in.)
Weight
- 514 g (1.1 lb)
Certifications
- CE
- FCC
- Shock (IEC 60068-2-27)
- Freefall (IEC 60068-2-32)
- Vibration (IEC 60068-2-6)
Warranty