Oring TES-150-M12ORing’s TransporterTM series Ethernet switches are designed for industrial applications, such as rolling stock, vehicle, and railway applications.  TES-150-M12 is an unmanaged Ethernet switch with 5×10/100Base-T(X) ports which is compliant with EN50155 request.  It is specifically designed for the toughest industrial environments.  TES-150-M12 EN50155 Ethernet switch use M12 connectors to ensure tight, robust connections, and guarantee reliable operation against environmental disturbances, such as vibration and shock.  In addition, the wide operating temperature range from -40oC to 70oC can satisfy most of operating environment.  The TES-150-M12 can be easily adopted in almost all kinds of applications and provides the most rugged solutions for your network.  Therefore, the switch is one of the most reliable choices for rolling stock Ethernet application.

Feature :

  • Industry-leading EN50155-compliant Ethernet switch for railway applications
  • Supports auto-negotiation and auto-MDI/MDI-X
  • Supports store-and-forward transmission
  • Supports flow control
  • M12 connectors to guarantee reliable operation against environmental disturbances
  • Ultra-rugged enclosure for toughest industrial usages
  • Wall mounting enabled

Specification :

ORing Switch Model TES-150-M12
Physical Ports
10/100 Base-T(X) Ports in M12 (D-coding) Auto MDI/MDIX 5
Technology
Ethernet Standards IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX
IEEE 802.3x for Flow control
Processing Store-and-Forward
LED Indicators
Power Indicator Green : Power LED x 1
10/100Base-T(X) M12 Port Indicator Green for port Link/Act. Amber for Duplex/Collision
Power
Power Input 12 ~ 48 VDC voltage power input in M12 connector (A-coding)
Power Consumption (Typ.) 3 Watts
Overload Current Protection Present
Reverse Polarity Protection Present
Physical Characteristic
Enclosure IP-40
Dimension (W x D x H) 88.9(W) x 40(D) x 178.2(H) mm
Weight (g) 360g
Environmental
Storage Temperature -40 to 85°C (-40 to 185°F)
Operating Temperature -40 to 70°C (-40 to 158°F)
Regulatory approvals
EMI FCC Part 15, CISPR (EN55022) class A, EN50155 (EN50121-3-2, EN55011, EN50121-4)
EMS EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-9, EN61000-4-11
Shock IEC60068-2-27, EN61373
Free Fall IEC60068-2-32
Vibration IEC60068-2-6, EN61373
Safety EN60950-1
Warranty 5 years