IMC-121FB series are industrial media converters providing media conversion between 10/100Base-T(X) and 100Base-FX. IMC-121FB series feature rigid IP-30 housing design and support wide operating temperature range from -40 to 70˚C. Therefore, IMC-121FB series are reliable media converter and can satisfy most demands of operating environments.
Feature :
- Support 2 ports 10/100Base-T(X) auto-negotiation and auto-MDI/MDI-X
- 2×10/100 Base-T(X) ports to save the usage of copper ports
- High reliability and rigid IP-30 housing
- DIN-Rail and wall mounting enabled
Specification :
ORing Media Converter Model | IMC-121FB-MM-SC | IMC-121FB-SS-SC |
Physical Ports | ||
10/100Base-T(X) Ports in RJ45 Auto MDI/MDIX | 2 | 2 |
Fiber Ports Number | 1 | 1 |
Fiber Ports Standard | 100Base -FX | 100Base -FX |
Fiber Mode | Multi-mode | Single-mode |
Fiber Diameter (μm) | 62.5/125 μm 50/125 μm | 9/125 μm |
Fiber Optical Connector | SC | SC |
Typical Distance (km) | 2 km | 30 km |
Wavelength (nm) | 1340 dBm | 1310 nm |
Max. Output Optical Power (dBm) | -14 dBm | -8 dBm |
Min. Output Optical Power (dBm) | -31 dBm | -15 dBm |
Max. Input Optical Power(Saturation) | 0 dBm | 0 dBm |
Min. Input Optical Power(Sensitivity) | -31 dBm | -34 dBm |
Link Budget (dB) | 7.5 dB | 19 dB |
WLAN interface | ||
Ethernet Standards | IEEE 802.3 for 10Base-T IEEE 802.3u for 100Base-TX and 100Base-FX |
|
LED Indicators | ||
10/100Base-T(X) RJ45 Port Indicator | Green : Power LED x 2 | |
100Base-FX Fiber Port Indicator | Green for port Link/Act. Amber for Duplex/Collision | |
Power | ||
Redundant Input Power | Dual 12~48 VDC power input at 4-pin terminal block | |
Power Consumption (Typ.) | 4.5 Watts | |
Overload Current Protection | Present | |
Reverse Polarity Protection | Present | |
Physical Characteristics | ||
Enclosure | IP-30 | |
Dimensions (W x D x H) | 26.1 (W) x 70 (D) x 95 (H)mm (1.03 x 2.76 x 3.74 inch) | |
Weight (g) | 210 g | |
Environmental | ||
Storage Temperature | -40 to 85°C (-40 to 185°F) | |
Operating Temperature | -40 to 70°C (-40 to 158°F) | |
Operating Humidity | 5% to 95% Non-condensing | |
Regulatory Approvals | ||
EMI | FCC Part 15, CISPR (EN55022) class A, | |
EMS | EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 | |
Shock | IEC60068-2-27 | |
Free Fall | IEC60068-2-32 | |
Vibration | IEC60068-2-6 | |
Safety | EN60950-1 | |
Warranty | 5 years |