EDS-316-M-SC16-port Unmanaged Ethernet switch with 16 10/100BaseT(X) ports, 0 to 60°C operating temperature

The EDS-316 are 16-port Ethernet switches that provide an economical solution for your industrial Ethernet connections. The built-in relay warning function alerts network engineers when power failures or port breaks occur, and the switches are designed for harsh industrial environments. The switches comply with FCC, TÜV, UL, and CE standards, and come in two model types. Standard operating temperature range models (0 to 60°C) and wide operating temperature range models (-40 to 75°C). Both models undergo a 100% burn-in test to ensure that they fulfill the special needs of industrial automation control applications. The EDS-316 switches can be installed easily on a DIN-rail or in a distribution box.

Feature :

The Green Core Product Identity of the EDS series will be phased in starting May 1, 2014. During the product transition period, you may still receive products that use the previous panel design. Please click here to learn more about Moxa’s Green Core product transition.

Features and Benefits  

  • Relay output warning for power failure and port break alarm
  • Broadcast storm protection
  • Transparent transmission of VLAN tagged packets
  • -40 to 75°C operating temperature range (T models)

Diagram :

Diagram EDS-316-M-SC-1

Diagram EDS-316-M-SC-2

Specification :

• Technology
Standards IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for Flow Control
Processing Type Store and Forward
Flow Control IEEE 802.3x flow control, back pressure flow control
• Switch Properties
MAC Table Size 4 K
Packet Buffer Size 1.25 Mbit
• Interface
Fiber Ports 100BaseFX ports (SC/ST connector)
RJ45 Ports 10/100BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto MDI/MDI-X connection
DIP Switches • Port break alarm mask
• Enable/disable broadcast storm protection
LED Indicators PWR1, PWR2, FAULT, 10/100M (TP port), 100M (fiber port)
Alarm Contact 1 relay output with current carrying capacity of 1 A @ 24 VDC
• Optical Fiber
Table
• Power Requirements
Input Voltage 12/24/48 VDC (9.6 to 60 VDC), redundant dual inputs
Input Current EDS-316: 0.27 A @ 24 V
EDS-316-M/S/MM/SS/MS: 0.44 A @ 24 V
Overload Current Protection 1.6 A
Connection 1 removable 6-pin terminal blocks
Reverse Polarity Protection Present
• Physical Characteristics
Housing Metal, IP30 protection
Dimensions 80.1 x 135 x 105 mm (3.15 x 5.31 x 4.13 in)
Weight 1140 g
Installation DIN-rail mounting, wall mounting (with optional kit)
• Environmental Limits
Operating Temperature Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
• Standards and Certifications
Safety UL 508, UL 60950-1, CSA C22.2 No. 60950-1, EN 60950-1
Hazardous Location UL/cUL Class 1 Division 2 Groups A/B/C/D,
ATEX Zone 2 Ex nA nC IIC T4 Gc
EMI FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) (EDS-305/308: Level 2; EDS-309/316: Level 3)
Marine DNV, GL
Shock IEC 60068-2-27
Freefall IEC 60068-2-32
Vibration IEC 60068-2-6
Note Please check Moxa’s website for the most up-to-date certification status.
• MTBF (mean time between failures)
Time 257,000 hrs
Database MIL-HDBK-217F, GB 25°C
• Warranty
Warranty Period 5 years
Details See www.moxa.com/warranty